manuel du multiparamètre analyseur d'eau en ligne uv300
détails techniques et spécifications du uv300
Contenu du document
ANAEL
ZI-15 rue Nobel-45700 Villemandeur
Tel: 02 38 85 77 12
Fax: 02 38 85 99 65
Site web: www.analyse-en-ligne.com
Email: info@analyse-en-ligne.com
UV300 - multiparameter online water analyser
Dimensions: 360 mm x 200 mm x 420 mm
Key Features
- Automatic cleaning with sulfuric acid 5%
- Automatic zero
- Low maintenance
- Multiparameters: up to 14 parameters in one single unit
- Multiplexing: analyse up to 6 streams with one unit
Parts Number
- Basic unit: UV300 Basic unit (no measurement included)
Technical Specifications
- Sample flow recommended: 0 - 5 L/min
- Sample pressure: 0 - 4 Bar (0 - 1 Bar with sampling peristaltic pump)
- Sample temperature: 0 - 80 °C
- Operating temperature: 0 - 60 °C
- Wet part materials: Quartz, PP, PE, FPM(viton), PMMA, PVC
- Measuring interval: Continuous or periodic: 1 min to 720 min
- Memory: 5000 lines of measurements (up to 16 channels) with date and time
- Chemical consumption: Cleaning solution (5% sulfuric acid): 220 mL/day
- Maintenance interval recommended: 6 months to 1 year (except for refilling)
- Power supply: 100 - 240 VAC ± 10% / maxi 60 VA / 50 - 60 Hz, 12 VDC 3A max
- Screen: Colour TFT LCD 320x240 pixels with LED backlight
- Outputs: RS232 with MODBUS protocol, RS485 with MODBUS protocol, 4-20 mA output, Relays, pH/ORP modules
- Inputs: 4-20 mA input, RS485 for probes
- Free sockets: 12 free sockets for optional modules among 4-20 mA I/O, Relays, pH, ORP, conductivity
- EMC & Safety Standard: CE, EN61010-1, EN61326
- Enclosure: Stainless Steel 316L with epoxy coating, wall mounting bracket
- Weight: 20 to 30 kg depending on the configuration
Optional Modules
- MI4-20 Isolated 4-20 mA input module - Input resistance: 100 ohm
- MIL Double logical inputs module - Input no 1: external pulse command for measurement, Input no 2: measurements inhibition, Isolated 0 - 48 VDC inputs, Impedance: > 10 Kohm
- MO4-20 Isolated 4-20 mA output module - Active output, max load 500 ohm
- MRELAY Relay module - Contact rating: 2 A/220 V, Maximum 6 relays modules allowed
- MCOND Conductivity module - Range: 0 – 100 µS/cm to 0 – 100 mS/cm, ATC input for platinum RTD 100 Ohm
- MORP ORP module - Range: -2000 mV to +2000 mV, ATC input for platinum RTD 100 Ohm
- MPH pH module - Range: 0 – 14, ATC input for platinum RTD 100 Ohm
- M-232-485 Converter module from RS232 to RS/422/485
2 years operation spare parts
- T-TYG-1 Tygon tube 3.2x6.4 mm - 1 meter
- P-ACI-HD-1 Head of cleaning peristaltic pump or reagent pump
- T-PHAR-1 Pharmed tube 6.4x9.6 mm - 0.75 meters (for optional sampling pump)
Analytical Parameters
- UV254: Standard range 0 - 200 Abs/m, Other ranges on request, Zero value: 0,50 Abs/m, Accuracy: ± 0,10 Abs/m
- Optical parameters such as UV254 UV Absorbance, Poly Aromatic Hydrocarbons UV Fluorescence, Chlorophyll A UV Fluorescence, and more are supported