Document
FP-VANNE-DECOLMATAGE-TARAUDE-SERIE-200
Contenu du document
VANNE DE DÉCOLMATAGE
TAURAUDÉE SÉRIE 200
MECAIR
PROTECTION
MANUTENTION FILTRATION
PROTECTION I MANUTENTION I FIL
VRAC
wwwpmfil.
2
02
MECAIR THREADED VALVES
200 SERIES
DESCRIPTION
The 200 SERIES is a range of
diaphragm valves suitable for dust
collector applications, in particular
for reverse pulse-jet filter cleaning
of filter bags, cartridges, envelope
filters, ceramic filters and sintered
metal fibre filters. The 200 Series valve
has the inlet port at 90° to the outlet
port. The 200 Series range comprises
6 models, from ¾? to 2½? , all with
threaded female Gas connections. The
1½? model is available in single and
double diaphragm versions, while the
2 ? and 2½? are all double diaphragm
valves. The special design assures an
extremely fast opening time, high flow
rates and easy installation. The valves
are constructed in diecast aluminium
and have an anodised protection
treatment which protect them from
corrosive and environmental agents.
Bolts and screws are in stainless steel.
The 200 Series is available in the
following versions:
• VNP, with integrated solenoid pilot
• VEM, with remote pneumatic
connection.
Upon request: Integral pilot valves with ATEX Certification:
• ATEX II 3 D (94/9/CE); for the above approved model the
correct code to use is VEM+ PV 24V/DCX (solenoid coil is
24 V-DC/18 W and DIN connector in conformity with the
ATEX Directive 94/9/CE) (PLG11-ATEX). Remote pilot valves
meet the requirements of: • ATEX II 2 GD when mounted
with PXA Pilot or CXD Enclosure (94/9/CE).
GENERAL CHARACTERISTICS
Fluids Filtered air and oil free
Diaphragm Standard
Nitrile: ?20° C/+ 80°C
Optional
Viton: ?30° C/+ 200° C
Pressure range From 0.5 to 7.5 bar
CONSTRUCTION FEATURES – VALVE
Cover Diecast aluminium (anodised)
Body Diecast aluminium (anodised)
Pilot base Aluminium (anodised)
Pilot Stainless steel
Diaphragm NBR
Bolts and screws Stainless steel
Diaphragm backing disk Stainless steel
Diaphragm spring Stainless steel
ELECTRICAL CHARACTERISTICS – SOLENOID
Coil insulation Class H
DIN socket connector Pg9 connection (cable entry)
DIN socket standard EN175301 - 803 (previously DIN 43650A) / A/ISO 4400
DIN socket optional 94/9/CE ATEX II 3GD T6
Isolation class DIN socket VDE 0110 - 1/89
DIN socket protection IP65 EN60529
Voltage range 12 V DC (supply +10% max.) 18 W
24 V DC (supply +10% max.) 18 W
48 V DC (supply +10% max.) 18 W
110 V DC (supply +10% max.) 18 W
24 V 50/60 Hz (supply +10% max.) 38/31 VA
48 V 50/60 Hz (supply +10% max.) 41/32 VA
115 V 50/60 Hz (supply +10% max.) 63/53 VA
220/240 V 50/60 Hz (supply +10% max.) 46/37 VA
Ambient temperature ?20° C/+ 60°C
TYPE PORT
SIZE Ø No.
DIAPH. PRESSURE RANGE (BAR) WEIGHT
kg COIL
KVCV
min. max.
VNP206¾? 1 0.57.50.55YES1011.6
VNP208 1? 1 0.57.50.65YES2124.4
VNP212 1½?10.57.51.4YES3743.0
VNP214 1½?20.57.51.5YES4451.2
VNP216 2? 2 0.57.52.5YES7890.7
VNP220 2½?20.67.53.3YES96112
VEM206 ¾? 1 0.57.50.25NO1011.6
VEM208 1? 1 0.57.50.35NO2124.4
VEM212 1½?10.57.51.1NO3743.0
VEM214 1½?20.57.51.2NO4451.2
VEM216 2? 2 0.57.52.2NO7890.7
VEM220 2½?20.67.53NO96
112
HOW TO ORDER
VEM/VNP 2 08 110/50
Voltage and frequency required
Valve connection diameter
• 06 = ¾ • 08 = 1
• 12 = 1½ (single diaphragm)
• 14 = 1½ (double diaphragm)
• 16 = 2 • 20 = 2½
Part Number Code:
Valve
N VNP – with integral pilot
E VEM – without pilot
2
“200 Series”
Lock nut
FILTRATION
3
03
DIMENSIONSVNP 206 - 208 - 212 VEM 206 - 208 - 212
VNP 214 - 216 - 220 VEM 214 - 216 - 220
MODELØ ABCDEFWEIGHT
kg MODEL
EØ LWEIGHT
kg PRESSURE RANGE
(BAR) No.
DIAPH.
min. max.
VNP 206 ¾? 41 7518119600.55 VEM 20659¼? 0.25 0.57.51
VNP 208 1? 529023123740.65 VEM 208 63 ¼? 0.35 0.57.51
VNP 212 1½? 72130311531351.40 VEM 21293¼? 1.10 0.57.51
VNP 214 1½? 72130311861351.50 VEM 214 126 ¼? 1.20 0.57.52
VNP 216 2? 90165352061602.50 VEM 216146¼? 2.20 0.57.52
VNP 220 2½? 116199472261903.30 VEM 220166¼? 3.00 0.67.52
MECAIR THREADED VALVES
200 SERIES
FILTRATION
4
04
SPARE PARTSVEM/VNP 206 - 208 - 212 VEM/VNP 214 - 216 - 220
STANDARD VERSION
POSDESCRIPTION CODE
Standard
1a)
Sol enoid (*) a) KIT SB4 - ../.. (*) -18 W
b) Pilot group complete with
base and ferrule b)
KIT CP1/4
c) DIN connector
PG9EN175301-803 IP65c)
KIT PLG9
(*) Specify voltage and frequency.
OPTIONAL VERSION
POS DESCRIPTION CODE
Optional
1a)
Sol enoid (*) a) KIT SB4 -24/DCX -18 W
b) Pilot group complete with
base and ferrule b)
KIT CP1/4
c) DIN connector (3GD IP65 T6) c) KIT PLG11 – ATEX
(*) Specify voltage and frequency.
Version in conformity with European Directive 94/9/CE ATEX (cod. KIT PV-24/DCX)
POS DESCRIPTION CODE
VEM/VNP206 VEM/VNP208VEM/VNP212VEM/VNP214VEM/VNP216VEM/VNP220
1Pilot group complete
with solenoid (*) and DIN
connector KIT
PV - ../..
(*) KIT
PV - ../..
(*) KIT
PV - ../..
(*) KIT
PV - ../..
(*) KIT
PV - ../..
(*) KIT
PV - ../..
(*)
a+b+4 Pilot group complete with
solenoid (*), top cover and
screws
KIT PVM06 - ../..
(*) KIT
PVM08 - ../..
(*) KIT
PVM12 - ../..
(*) KIT
PVM06 - ../..
(*) KIT
PVM06 - ../..
(*) KIT
PVM06 - ../..
(*)
2 Valve body KIT M100201 KIT M100204 KIT M100211 KIT M100211 KIT M100218 KIT M300222
7 Intermediate cover
(double diaphragm) —
—— KIT M110098 KIT M110100 KIT M110101
4 Top cover KIT M110082 KIT M110086 KIT M110092 KIT M110082 KIT M110082 KIT M110082
5 Diaphragm KIT DB 16/G KIT DB 18/G KIT DB 112/G — ——
5 Viton Diaphragm KIT DB 16V/S KIT DB 18V/S KIT DB 112V/S — ——
5 + 6+ Spring Diaphragm
(main and secondary) —
——KIT DB 114/C KIT DB 116/C KIT DB 120/C
5 + 6+ Spring Viton Diaphragm (main
and secondary) —
——KIT DB 114V KIT DB 116V KIT DB 120V
(*) Specify voltage and frequency.
MECAIR THREADED VALVES
200 SERIES
FILTRATION
99
ZA - 45160
T
00F000E1
wwwpm.
PROTECTION I MANUTENTION I FIL
Entreprise(s) concernée(s) :
Produit(s) concerné(s) :
Date d'upload du document :
mardi 2 février 2021